Move the dome manually, and check if the dome alarm in the 60" control room sounds as the dome rotates.
Reset the VITRAX controller and retry dome.
If the alarm sounds while turning the dome, the VITRAX is working. Try homing the dome. Make sure Track is ON on TCS60. The dome will not move unless this is on. Look at dome az in the ninst.setup window. The last number there should match dome az on TCS60. If all else fails, physically cycle power to flwo60 with a godown. If nothing else works, you can always move dome manually.
VITRAX
DOME CONTROL MICROPROCESSOR
Final control of the 60" dome happens using a VITRAX single board microproccesor. This computer does little except service the dome encoder, and actually move the dome. It gets input from the flwo60 PCTCS program, and input consists of three digit number that represents dome azimuth. If the vitrax has a problem, it will fall into one of the two following catagories.
In the this case, the dome position is off, and all you need to do is turn off track, and move the dome to the right 360 degrees, then turn track back on. It will reset dome position when the hall-effect sensor passes behind the polar axis.