1.0 Introduction
1.1 Spectrograph Characteristics
FAST has a conventional plane reflection grating geometry with an
off-axis parabolic collimator and a Schmidt camera. The focal length of
the collimator is 963 mm and the effective focal length of the camera is
328 mm, giving a reduction of 2.93, corresponding to a scale of 0.57
arcsec/15 pixel along the slit. The unvignetted slit length is 3
arcminutes, or 13.72 mm at the slit. The angle between the collimated
beams arriving at and leaving the grating is 35
. The layout
of the spectrograph is shown in Figure 1.
1.2 Gratings
FAST is designed to accept gratings with rulings between 300 and 1200
lines per mm in first order. Table 1 gives the resolutions and spectral
coverages for various gratings with a 40 mm long CCD, such as the Loral
5122688. The spectrograph will vignette at the spectral
extremes if a grating with an anamorphic factor exceeding 1.3 is used.
This corresponds to a 1200 line grating centered at H
, so
that the use of a 1200 line grating in the extreme red will entail a
modest loss in efficiency.
Ruling | 2 Pixel Res | Spectral Coverage | 2 Pixel Slit Width |
300 gpm | 2.95 ![]() |
4000 ![]() |
1.21 arcsec |
600 gpm | 1.49 ![]() |
2000 ![]() |
1.25 arcsec |
1200 gpm | 0.75 ![]() |
1000 ![]() |
1.52 arcsec |
We currently have three gratings available: a 300 and 600 line grating
blazed at 4750 , and a 1200 line grating blazed at 5700
. The
300 and 600 line gratings have 50% efficiency limits of 3500 and 8000
, and the 1200 line grating has 50% efficiency limits of 4000 and
10000
. Figure 2 shows the efficiency of the gratings as a
function of wavelength. The gratings can be changed manually through
the access hatch of the spectrograph.
1.3 Efficiency
FAST was designed for high throughput between 3700 and 9000,making use of high efficiency antireflection coatings and UV enhanced,
over coated silver coatings for the mirrors. With a thinned, back-side
illuminated CCD with antireflection coating, the peak efficiency
(including detector) will exceed 40%. With a thick, front side
illuminated CCD, the peak efficiency reaches
20%, but falls off
severely in the blue. Figure 3 gives a plot of the efficiency
versus wavelength with the current, thin CCD.
1.4 CCD Characteristics
The current CCD is a 3242720 chip with 15
pixels.
The CCD operating temperature is
115
K, giving a dark current of a few electrons/hr/pixel. The
noise of the CCD is
8.6 electrons RMS. The CCD gain is currently
set to 1.2 electrons per ADU.
1.5 Slits
There are five fixed-width slits available: 1.1, 1.5, 2, 3, and 5 arcseconds wide. These can be changed manually through the access hatch of the spectrograph. The resolution versus slit width for a 300 gpm grating is given in the following table. It will be slightly better with more finely ruled gratings.
Slit Width | Pixels |
(arcsec) | FWHM |
1.1 | 2.0 |
1.5 | 2.3 |
2.0 | 2.8 |
3.0 | 4.2 |
5.0 | 7.4 |
1.6 Blocking Filters
We have on order two long pass filters available with cutoffs of 3700 and 5000
. These are mounted in a slide between the slit and the shutter.
1.7 Automated Features
The collimator focus and the comparison stage can be remotely operated via computer, as can the three calibration lamps (He-Ar, Ne, and Incand).
2.0 Calibration Lamps
The wavelength comparison lines are produced by a He-Ne-Ar lamp.
Figure 4 is a spectral line atlas over most of the useful spectral range with the 300 gpm grating and Figure 4 is an atlas in the UV and blue with the 1200 gpm grating to resolve some blended lines. Note the presence of some Fe lines in the UV; these are produced by the Fe cathode in the He/Ar lamp.
The incandescent lamp unfortunately is weak below 4500 , even
after the introduction of a color balancing filter. Bluer filters are
available, but the filters we tried introduced strong variations in
intensity with periods of several hundred
. We felt that most users
would prefer to make multiple flat exposures rather than deal with
strong short period intensity variations. The incandescent lamp is quite
bright, requiring an exposure of
0.2 seconds. Bas is adding
lamps and a white screen for dome flats.
All lamps are fed into an integrating sphere to scramble the lamp outputs and then pass through an achromatic lens to simulate the exit pupil of the telescope. This should produce an accurate calibration. Please be aware, however, that no calibration lamp is perfect, and that wavelength shifts between the sky and the lamps will be present at some level. A good way to check for offsets is to look at the calibrated wavelengths of known strong lines in the spectrum of the night sky. We have verified that the spectrograph flexure as measured by the comparison lamps tracks the flexure measured by night sky lines quite accurately.
All light from the integrating sphere passes through a 1 mm thick BG-14 filter. This reduces the intensity of the strong red comparison lines and provides some color balancing for the incandescent lamp.
3.0 Focusing and Wavelength Stability
The spectrograph case is constructed from low-expansion graphite-epoxy
composite panels with a coefficient of thermal expansion less than 25%
that of aluminum. During the first run of FAST on the telescope we
noticed only a small defocus resulting from a change from the lab
temperature of 20 to the 0
C typically encountered at
night. As a result, the spectrograph will stay in focus over the
temperature changes occurring on a typical run. The graphite epoxy
composite will expand and contract with humidity changes, but this is a
slow process that should not be noticeable in a single run.
Each step of the stepper motor that controls the collimator focus
corresponds to a movement of 10 . Given that the telescope is
f/10, that the reduction is 2.9 and the 15
pixel size, it will
probably not be necessary to focus in moves smaller than 10-20
steps.
FAST was designed to achieve good short term stability, that is: good
stability over the course of the longest anticipated exposure, about one
hour. There are two major contributors to this stability: mechanical
flexure and thermal shifts. The measured mechanical flexure averages
0.3 pixel per 15 of tilt (4.5
m), which corresponds to an
hour of tracking an object. For short exposures, it will probably be
necessary to take only a single HeNeAr comparison exposure. The flexure
is largest moving from E to the zenith and N to the zenith, and almost
absent moving to the S from the zenith. There is a small amount of
hysteresis (
0.2 pixels) as the telescope returns to the zenith
from different directions.
We have measured the thermal stability of the spectrograph in the
laboratory and find a 0.2 pixel/C shift, close to what we
calculated should be present. Given that the night-time temperature
changes are typically 0.25
C/hour during the night, this should
not be significant even for a long exposure. The thermal time constant
of the spectrograph is about 3.5 hours, so if the dome is allowed to
heat up significantly during the day, it would be wise to open the dome
as soon as possible if the maximum stability is required. Opening the
dome near sunset will also help the seeing.
4.0 Changing Slits and Gratings
Changing gratings requires great care. In general, you should ask the staff to change the gratings for you during the day. In special cases, you may obtain permission to change slits or gratings after receiving training from the day staff and from the remote observers. Also, do read and make sure you understand the instructions below as a first step. If you are feeling clumsy or groggy, do not ever attempt to change gratings. Gratings cost $5000 or more and their replacement time is long.
Gratings and slits are installed through the single removable panel on
the spectrograph. This panel is secured with two handles that rotate by
90 between open and closed. The access panel must be completely
removed and placed in a safe location before proceeding further. The
slits are held in place by spring-loaded plungers; the slit is simply
pulled out by grasping its handle. The new slit should be inserted
reflective side up and pushed home. The filter slide, mounted below the
slit, is removed and installed in the same fashion.
Before removing a grating, remove heavy jackets as the access port will not accommodate down jackets and heavy sweaters. Remember that vulnerable optics are exposed beneath the grating. Please do not drop your flashlight, pens, etc. into the spectrograph!
Gratings are stored inside the chamber. You will find them with their covers closed. These are held closed by magnets. They can be pried open with gentle force, once the grating is mounted on the spectrograph. The first step of removal of a grating must be to close its cover. To close it, just swing the cover up until the magnets catch.
The grating is secured with two bolts, one in back and one just inside
the access panel. These two bolts must be loosened so that the grating
rests on the slides that guide it into position. The arm that carries
the forward bolt is then pushed up and rotated 90 to the right
until the spring plunger seats, holding it out of the way. The grating
can then be carefully removed and stowed away. Make sure you look inside
the spectrograph with adequate light to ensure the grating cover is closed,
otherwise you may add your own fingerprints to the collection already on
some of the gratings. Note that if you ever do this, you should not
attempt to clean the grating in any way, and you should notify the
staff of the mishap.
To install the new grating, reverse the removal procedure. Take care that the grating does not twist from side to side as it is inserted or it will bind. Tighten the two grating bolts gradually, alternating so that the grating seats properly in its kinematic mount. Do not overtighten the bolts: firm finger tightening is sufficient! The last step should be to open the grating cover.
5.0 Setting Grating Central Wavelengths
The grating tilt (and hence wavelength coverage) is adjusted with a manual, digital-readout micrometer. Each digit corresponds to a 0.001 inch adjustment. Two different styles of micrometers are used: the style used with the 300 and 600 gpm gratings have a locking ring, while the other style used for the 1200 gpm grating does not. We expect that the 1200 gpm grating micrometer has sufficient internal friction to prevent undesired rotation. Please alert us if you have any doubts on this score. The locking ring is loosened with a counterclockwise rotation. If the micrometer does not turn freely, do not force it. Please loosen the ring. The equations to calculate the correct micrometer setting are given below:
300 gpm grating:
600 gpm grating:
1200 gpm grating with no spacer (5400-7000):
1200 gpm grating with 0.45 inch spacer (4000-7000):
Please ask the staff to make sure the 0.45 inch spacer is in
place if you wish to use the 1200 gpm grating in the blue. Slightly
improved thermal stability will be possible if you take the spacer out
for observations near H, but the convenience of not fussing
with the spacer may override this modest gain.
6.0 Scattered Light
Scattered light in the spectrograph results from undesired reflections from the refractive optics and the CCD, imperfections in the reflective surfaces and scattering of light outside first order from the spectrograph case. We have minimized these sources of scattered light as far as we know how, but some remains. Scattered light amounting to 3% of the dispersed light is scattered fairly uniformly across the CCD surface. Only about 1% of this scattered light (or 0.03% of the dispersed light) will fall on top of the desired spectrum, but strong sky lines may contribute as well.